Biolit® Random Hexamer Primer 6-Mer (50 µM) | 53704 | SRL Chem

SRL Chemicals Dealer | eqipped

Biolit® Random Hexamer Primer 6-Mer (50 µM) | 53704 | SRL Chem

High-purity 6-mer random hexamer primer (50 µM) for reliable cDNA synthesis. Ideal for RT-PCR, cloning, and molecular biology applications.

2,260.00

Description

Specifications Table

Product NameBiolit® Random Hexamer Primer 6-Mer (50 µM)
Quantity/Pack Size50 µl
FormLiquid
GradeMolecular Biology Grade
ApplicationcDNA synthesis, RT-PCR, cloning

Product Description

When it comes to molecular biology research, the quality of your primers can make or break your experiments. The Biolit® Random Hexamer Primer 6-Mer (50 µM) is a high-performance solution designed for researchers, students, and educators who demand precision in cDNA synthesis. Whether you’re working on gene expression studies, cloning, or RT-PCR, this 6-mer random hexamer primer ensures consistent and reliable results.

Random hexamer primers are essential for reverse transcription, providing a universal starting point for cDNA synthesis from RNA templates. Unlike gene-specific primers, these 6-mer sequences bind randomly to RNA, making them ideal for applications where the target sequence is unknown or when full-length cDNA is required. The 50 µM concentration offers flexibility, allowing you to adjust volumes based on your experimental needs.

At eqipped, we understand the importance of reproducibility in lab work. That’s why we source this primer from SRL Chem, a trusted name in molecular biology reagents. Each batch is rigorously tested to ensure purity and performance, so you can focus on your research without worrying about inconsistent results.

Need a reliable random hexamer primer for your next experiment? Order the Biolit® 6-Mer Primer today and experience the difference in your cDNA synthesis workflow.

How Random Hexamer Primers Work

Random hexamer primers are short, single-stranded DNA sequences (typically 6 nucleotides long) that anneal randomly to RNA templates. This random binding allows for the synthesis of cDNA from all RNA molecules in a sample, making them particularly useful for:

  • Full-length cDNA library construction
  • Gene expression profiling
  • RT-PCR and qPCR applications
  • Cloning and sequencing

The Biolit® Random Hexamer Primer is optimized for high efficiency, ensuring robust cDNA yields even from low-input RNA samples. Its 50 µM concentration provides enough material for multiple experiments, making it a cost-effective choice for labs of all sizes.

Why Use a 6-Mer Random Hexamer Primer?

While longer random primers (e.g., 9-mers or 12-mers) are available, 6-mer primers offer several advantages:

  • Better coverage Short primers bind more frequently across the RNA template, reducing bias in cDNA synthesis.
  • Lower secondary structure interference Shorter primers are less likely to form stable secondary structures, improving annealing efficiency.
  • Ideal for fragmented RNA Works well with degraded or short RNA fragments, common in FFPE samples.

For researchers working with challenging samples, this primer is a game-changer. Whether you’re analyzing ancient DNA, degraded clinical samples, or low-abundance transcripts, the Biolit® 6-Mer Primer delivers consistent performance.

Applications in Research and Education

This versatile primer is a staple in both research labs and educational settings. Here’s how it’s commonly used:

  • RT-PCR and qPCR Convert RNA to cDNA for downstream amplification and quantification.
  • RNA-Seq library prep Essential for next-generation sequencing workflows.
  • Cloning and gene expression studies Generate cDNA for cloning into vectors or expression analysis.
  • Teaching labs A reliable tool for students learning molecular biology techniques.

At eqipped, we’ve seen this primer used in everything from undergraduate lab courses to high-throughput research projects. Its ease of use and reliability make it a favorite among both beginners and experienced researchers.

Storage and Handling

To maintain the integrity of your Biolit® Random Hexamer Primer, follow these storage guidelines:

  • Store at -20°C for long-term stability.
  • Avoid repeated freeze-thaw cycles to prevent degradation.
  • Aliquot if frequent use is expected.

Proper handling ensures that your primer remains effective throughout its shelf life, giving you consistent results every time.

Compatibility with Other Reagents

This primer is compatible with most reverse transcriptase enzymes, including:

  • M-MLV Reverse Transcriptase
  • AMV Reverse Transcriptase
  • SuperScript™ series enzymes

Pair it with your preferred RT enzyme and buffer system for seamless integration into your existing protocols.

Risk Note

This product is for research use only. Not for diagnostic or therapeutic applications. Handle with standard laboratory precautions.

FAQs

What is a random hexamer primer used for?

A random hexamer primer is used for cDNA synthesis from RNA templates. It binds randomly to RNA, allowing reverse transcriptase to generate complementary DNA (cDNA) for applications like RT-PCR, cloning, and sequencing.

How does the Biolit® 6-Mer Primer compare to longer random primers?

The 6-mer primer offers better coverage and efficiency with fragmented or low-quality RNA. Longer primers may provide more stable annealing but can introduce bias in cDNA synthesis.

Can I use this primer for qPCR?

Yes, the Biolit® Random Hexamer Primer is suitable for qPCR applications. It ensures efficient cDNA synthesis, which is critical for accurate quantification in downstream qPCR assays.

What is the shelf life of this product?

When stored at -20°C, the primer remains stable for up to 24 months. Avoid repeated freeze-thaw cycles to maintain its integrity.

Is this primer compatible with my RT enzyme?

This primer is compatible with most reverse transcriptase enzymes, including M-MLV, AMV, and SuperScript™ series. Always check your enzyme’s protocol for optimal conditions.

Do You Want Best Price?

Take 3 minutes to share your Details.