Description
Specifications Table
| Product Name | Cyclohexane GC Grade | Q48505 | Qualigens |
|---|---|
| Quantity/Pack Size | 500ml |
| Form | Liquid |
| Grade | GC Grade |
| Application | Gas Chromatography, Solvent Extraction, Lab Research |
Product Description
When your lab work demands precision, every detail matters. That’s where Cyclohexane GC Grade from Qualigens steps in—a high-purity solvent designed specifically for gas chromatography and other sensitive analytical applications. Whether you’re a researcher fine-tuning an experiment or a student setting up your first GC run, this 500ml pack ensures consistency and reliability in your results.
Cyclohexane is a non-polar solvent widely used in laboratories for its ability to dissolve a variety of organic compounds without interfering with analytical processes. The GC grade variant is rigorously purified to remove impurities like water, alcohols, and other hydrocarbons, making it ideal for baseline separation in chromatographic techniques. Unlike technical or industrial grades, this version meets strict quality benchmarks, so you can trust your data without second-guessing solvent interference.
At eqipped, we understand that lab supplies aren’t just products—they’re tools that shape discoveries. That’s why we source Cyclohexane GC Grade from Qualigens, a brand synonymous with quality in Indian laboratories. Whether you’re working in academia, pharmaceuticals, or environmental testing, this solvent helps maintain the integrity of your samples and the accuracy of your instruments.
Need a reliable solvent for your next GC analysis? Buy Cyclohexane GC Grade online today and experience the difference purity makes.
Why This Grade Matters in Your Lab
Not all cyclohexane is created equal. The GC grade is optimized for:
- Cleaner Chromatograms: Minimal background noise means sharper peaks and more accurate quantification.
- Consistent Retention Times: Low impurity levels ensure reproducible results across multiple runs.
- Instrument Longevity: Fewer contaminants reduce wear on GC columns and detectors.
If you’ve ever struggled with inconsistent results due to solvent impurities, switching to a dedicated GC grade can be a game-changer. It’s a small investment that pays off in data you can confidently publish or present.
Common Applications
This versatile solvent finds use in:
- Gas Chromatography (GC): As a mobile phase or for sample dilution.
- Spectroscopy: In IR and UV-Vis studies where solvent transparency is critical.
- Extraction Processes: For isolating non-polar compounds from mixtures.
- Synthesis: As a reaction medium in organic chemistry.
Students often use it in undergraduate labs for experiments involving solubility tests or recystallization, while researchers rely on it for more advanced applications like pesticide residue analysis or petroleum testing.
Handling and Storage Tips
To maintain the integrity of your Cyclohexane GC Grade, follow these best practices:
- Store in a Cool, Dry Place: Keep the bottle tightly sealed away from direct sunlight or heat sources.
- Use in a Well-Ventilated Area: Cyclohexane vapors can be harmful if inhaled in large quantities.
- Avoid Contamination: Always use clean, dedicated pipettes or syringes to dispense the solvent.
- Check for Moisture: If the solvent appears cloudy, it may have absorbed water—consider drying it with molecular sieves before use.
Proper handling not only extends the shelf life of your solvent but also ensures your experiments remain free from avoidable errors.
Safety First: A Quick Note
Cyclohexane is flammable and should be handled with care. Always wear appropriate PPE (gloves, goggles) and work in a fume hood when possible. In case of spills, use absorbent materials and dispose of waste according to local regulations. For detailed safety information, refer to the SDS provided with your order.
Why Lab Professionals Trust eqipped
When you buy cyclohexane or any lab supply from eqipped, you’re not just placing an order—you’re choosing a partner committed to your work’s success. We focus on:
- Genuine Products: Sourced directly from trusted brands like Qualigens.
- Fast, Reliable Delivery: Because your research can’t wait.
- Transparent Support: Have a question? Our team is just a call or chat away.
Thousands of students, educators, and researchers across India rely on us for supplies that meet their exacting standards. Whether you’re stocking up for a semester or scaling up a project, we’ve got you covered.
FAQs
What is the difference between GC grade and HPLC grade cyclohexane?
GC grade cyclohexane is purified to remove impurities that could interfere with gas chromatography, such as residual water or other solvents. HPLC grade, while also high-purity, is optimized for liquid chromatography and may have stricter limits on UV-absorbing contaminants. For GC applications, always use the GC grade to avoid baseline drift or ghost peaks.
Can I use this cyclohexane for recystallization?
Yes, cyclohexane is commonly used for recystallizing non-polar or moderately polar compounds. Its low polarity makes it ideal for purifying organic solids like hydrocarbons or some pharmaceutical intermediates. However, ensure the compound you’re recystallizing has suitable solubility in cyclohexane at different temperatures.
How long does a 500ml bottle last in a typical lab?
This depends on your usage. For routine GC analysis (e.g., 1-2ml per sample), a 500ml bottle can last for 250-500 runs. In teaching labs, where students might use larger volumes for extractions or cleaning, it may deplete faster. Storing it properly can prevent evaporation and extend its usability.
Is this cyclohexane suitable for UV spectroscopy?
While GC grade cyclohexane is highly pure, it may still contain trace impurities that absorb in the UV range. For UV spectroscopy, we recommend using a solvent specifically labeled as “UV grade” or “spectrophotometric grade” to avoid interference in your readings.
What should I do if my cyclohexane has turned yellow?
A yellow tint often indicates oxidation or contamination. Do not use it for critical applications. For GC work, discard the bottle and order a fresh one. If you’re using it for less sensitive tasks, you might purify it via distillation, but this isn’t recommended for GC-grade solvents.