Description
Specifications Table
| Product Name | Yttrium, plasma standard solution, Specpure®, Y 1000μg/ml |
|---|---|
| Pack Size | 500ml, 100ml, 50ml |
| Form | Liquid (aqueous solution) |
| Grade | Specpure® (high-purity, traceable) |
| Application | ICP-OES, ICP-MS, atomic absorption spectroscopy (AAS), trace metal analysis |
Product Description
When precision matters in your lab, the right standard solution can make all the difference. The Yttrium plasma standard solution (1000µg/ml) from Specpure® is designed for researchers, students, and educators who demand accuracy in trace metal analysis. Whether you’re calibrating instruments for ICP-OES, ICP-MS, or atomic absorption spectroscopy, this high-purity solution ensures reliable results every time.
Yttrium is a critical element in geochemical, environmental, and materials science research. This standard solution, manufactured by Thermofisher, adheres to rigorous quality controls, making it a trusted choice for laboratories across India. The Specpure® grade guarantees minimal interference from contaminants, so you can focus on your data without worrying about background noise.
Available in convenient pack sizes (50ml, 100ml, and 500ml), this solution is ready to use right out of the bottle. No dilution required for most applications, saving you time and reducing the risk of errors. For labs that need consistent performance, eqipped offers this standard solution with fast shipping and competitive pricing.
Upgrade your lab’s calibration standards today. Buy Yttrium standard solution 1000µg/ml online for precise, reproducible results.
Why This Yttrium Standard Stands Out
Not all standard solutions are created equal. Here’s what sets this Specpure® Yttrium solution apart:
High Purity for Accurate Results: The Specpure® grade ensures that the yttrium concentration is exactly 1000µg/ml, with negligible impurities. This is crucial for labs where even minor deviations can skew findings.
Versatile Applications: Compatible with multiple techniques, including ICP-OES, ICP-MS, and AAS. Whether you’re analyzing soil samples, industrial materials, or biological specimens, this solution delivers consistent performance.
Long Shelf Life: Stable under proper storage conditions, reducing waste and ensuring you always have a reliable standard on hand.
Traceable and Certified: Backed by Thermofisher’s reputation for quality, each batch comes with documentation for full traceability—a must for audits and compliance.
For educators, this solution is an excellent teaching tool. Students can learn calibration techniques with a standard that mirrors real-world lab conditions. Researchers will appreciate the reproducibility it brings to their experiments.
How to Use Yttrium Plasma Standard Solution
Using this standard is straightforward, but following best practices ensures optimal results:
Storage: Keep the bottle tightly sealed at room temperature (15–25°C). Avoid exposure to direct sunlight or extreme temperatures.
Handling: Use clean, dedicated pipettes to prevent cross-contamination. Always wear appropriate PPE (gloves, goggles) when handling chemical solutions.
Calibration: For ICP or AAS, prepare a calibration curve using serial dilutions of this stock solution. Most labs find that a 1000µg/ml stock simplifies workflows, as it can be diluted to lower concentrations as needed.
Disposal: Follow local regulations for chemical waste disposal. Never pour unused solution down the drain.
Need help selecting the right pack size? Eqipped’s team can guide you based on your lab’s usage. Shop now and get your standard delivered fast.
Common Applications in Indian Labs
Yttrium standards are widely used in:
Environmental Testing: Measuring yttrium levels in water, soil, and air samples to assess pollution or mineral content.
Materials Science: Analyzing alloys, ceramics, and superconductors where yttrium is a key component.
Geological Research: Studying rock formations and mineral deposits for rare earth element (REE) content.
Pharmaceuticals: Validating equipment used in drug manufacturing to ensure no metallic contaminants are present.
Academic Labs: Teaching students about spectroscopic techniques and quality control in analytical chemistry.
If your work involves any of these areas, this Specpure® standard is an investment in data integrity.
Safety and Handling
Risk Note: While yttrium is not highly toxic, this solution contains nitric acid as a stabilizer. Avoid skin contact, inhalation, or ingestion. In case of spillage, neutralize with a weak base (e.g., sodium bicarbonate) and clean up immediately. Store in a well-ventilated area away from incompatible substances.
Always refer to the Safety Data Sheet (SDS) provided with your order for detailed handling instructions.
FAQs
What is the shelf life of this Yttrium standard solution?
The solution remains stable for at least 2 years when stored unopened at room temperature. Once opened, use within 6 months for best accuracy.
Can I use this standard for both ICP-OES and ICP-MS?
Yes, this Specpure® Yttrium standard is suitable for both techniques, as well as atomic absorption spectroscopy (AAS).
Do I need to dilute this solution before use?
It depends on your application. For most calibrations, you’ll need to prepare working standards by diluting the 1000µg/ml stock. Always follow your method’s specific requirements.
Is this solution traceable to NIST or other standards?
Yes, Thermofisher’s Specpure® standards are traceable to NIST or other recognized reference materials, ensuring metrological reliability.
How quickly can I get this product delivered in India?
Eqipped offers fast shipping across India. Delivery times vary by location, but most orders arrive within 3–5 business days. Check your pin code at checkout for exact estimates.