															The Labtronics LT-1160 Bomb Calorimeter is designed for precise measurement of the heat of combustion of solid and liquid fuels. It delivers reliable and repeatable results, making it essential for chemical, fuel, and food analysis labs. With robust construction and user-friendly operation, it suits both academic and industrial applications. This high-performance instrument meets the standards for accurate calorific value testing.
₹155,000.00
| Feature | Specification | 
|---|---|
| Model | LT‑1160 | 
| Measurement Range | Suitable for fuels, food samples, biomass, and chemicals | 
| Temperature Resolution | Up to 0.001 °C | 
| Combustion Vessel | High‑pressure stainless‑steel bomb with safety valves | 
| Ignition System | Electric ignition with automatic oxygen filling | 
| Water Jacket | Double‑jacket with integrated stirrer for uniform temperature | 
| Compliance | ASTM D240, ASTM D5865, ISO 1928 | 
| Data Interface | USB / RS232 connectivity for PC integration and report export | 
| Display & Controls | Digital control panel with clear LCD display | 
| Safety Features | Pressure indicators, over‑pressure protection, corrosion‑resistant build | 
| Applications | Fuel testing, food calorific analysis, biomass R&D, academic demonstrations | 
The Labtronics LT‑1160 Bomb Calorimeter is a precision‑engineered solution for laboratories that demand accurate calorific value analysis. Whether in energy research, nutritional studies, or waste‑to‑energy programs, the LT‑1160 delivers reliable data and operational efficiency that modern labs require.
Using a sealed stainless‑steel bomb, the LT‑1160 measures heat of combustion by recording the temperature rise in a water jacket as the sample burns in an oxygen‑rich environment. Its high‑sensitivity temperature sensor and uniform stirring system capture even the smallest changes, enabling results with exceptional precision.
Fuel Analysis: Coal, coke, fuel oil, biomass, and waste‑derived fuels
Food Testing: Nutritional calorific value for product labeling
Environmental Labs: Energy potential of waste materials
Education & Research: Demonstrations of combustion and thermodynamic principles
A digital interface with automatic ignition, oxygen filling, and data logging reduces manual intervention, while built‑in safety valves and pressure indicators provide peace of mind. The stainless‑steel construction resists corrosion and wear, ensuring long‑term, high‑volume use.
The LT‑1160 complies with ASTM D240, ASTM D5865, and ISO 1928 standards, ensuring test results meet global benchmarks. USB/RS232 connectivity and PC software integration allow for data logging, graph plotting, and exportable reports, supporting GLP compliance and easy audits.
Despite its advanced functionality, the LT‑1160 maintains a compact footprint, fitting seamlessly into existing workflows. Its robust design, low maintenance needs, and competitive price point make it a smart investment for labs focused on efficiency and quality.
 High‑precision temperature resolution (0.001 °C)
 Automatic ignition, oxygen filling, and data capture
 Safety‑enhanced stainless‑steel combustion vessel
 Compliance with international test standards
 Integration with PC software for data management
Upgrade your lab with the Labtronics LT‑1160 Bomb Calorimeter to achieve dependable calorific measurements that support better decision‑making and regulatory compliance.
The Labtronics LT-671 Microprocessor Flame Photometer with a graphical display is engineered for fast and precise measurement of sodium and potassium ions in various sample solutions. Suitable for clinical labs, environmental analysis, and industrial testing, this instrument ensures high sensitivity and user-friendly operation for routine and advanced flame photometric applications.
Buy LT-39 Microprocessor Spectrophotometer (VIS) for advanced spectral analysis with a wavelength range of 320-1020 nm. Features a 3½ digit bright LCD display, automatic concentration measurement, and % Transmission, absorbance, and K factor analysis. Equipped with a sample holder for 10-50 mm cuvettes, unlimited data storage, and RS-232C printer connectivity.
The LT-2202 Double Beam UV-Vis Spectrophotometer comes with an 8-cell holder for enhanced sample handling. It operates in a wavelength range of 190-1100 nm, supporting basic and quantitative wavelength scans, DNA protein tests, and kinetic measurements. With automatic peak picking and a large graphical display, this instrument allows efficient data analysis. Spectrum data can be printed or transferred via USB for convenient storage and further processing. The system includes pre-installed software for easy operation.
Buy LT-38 Digital Spectrophotometer with a dual display for more accurate spectral analysis. Covering a wavelength range of 340-960 nm, it features a 3½ digit data display and a separate 3-digit LED display for wavelength readings with 1 nm resolution. Includes provisions for 10 mm & 50 mm cuvettes for flexible sample analysis.
The Labtronics LT-77 Digital Bulk Density Apparatus is a precision-engineered instrument used to determine the bulk density and tapped density of powders and granules. Ideal for pharmaceutical, chemical, and material testing labs, it ensures accurate, reproducible results with user-friendly operation.
 
															₹155,000.00
The Labtronics LT-1160 Bomb Calorimeter is designed for precise measurement of the heat of combustion of solid and liquid fuels. It delivers reliable and repeatable results, making it essential for chemical, fuel, and food analysis labs. With robust construction and user-friendly operation, it suits both academic and industrial applications. This high-performance instrument meets the standards for accurate calorific value testing.
| Feature | Specification | 
|---|---|
| Model | LT‑1160 | 
| Measurement Range | Suitable for fuels, food samples, biomass, and chemicals | 
| Temperature Resolution | Up to 0.001 °C | 
| Combustion Vessel | High‑pressure stainless‑steel bomb with safety valves | 
| Ignition System | Electric ignition with automatic oxygen filling | 
| Water Jacket | Double‑jacket with integrated stirrer for uniform temperature | 
| Compliance | ASTM D240, ASTM D5865, ISO 1928 | 
| Data Interface | USB / RS232 connectivity for PC integration and report export | 
| Display & Controls | Digital control panel with clear LCD display | 
| Safety Features | Pressure indicators, over‑pressure protection, corrosion‑resistant build | 
| Applications | Fuel testing, food calorific analysis, biomass R&D, academic demonstrations | 
The Labtronics LT‑1160 Bomb Calorimeter is a precision‑engineered solution for laboratories that demand accurate calorific value analysis. Whether in energy research, nutritional studies, or waste‑to‑energy programs, the LT‑1160 delivers reliable data and operational efficiency that modern labs require.
Using a sealed stainless‑steel bomb, the LT‑1160 measures heat of combustion by recording the temperature rise in a water jacket as the sample burns in an oxygen‑rich environment. Its high‑sensitivity temperature sensor and uniform stirring system capture even the smallest changes, enabling results with exceptional precision.
Fuel Analysis: Coal, coke, fuel oil, biomass, and waste‑derived fuels
Food Testing: Nutritional calorific value for product labeling
Environmental Labs: Energy potential of waste materials
Education & Research: Demonstrations of combustion and thermodynamic principles
A digital interface with automatic ignition, oxygen filling, and data logging reduces manual intervention, while built‑in safety valves and pressure indicators provide peace of mind. The stainless‑steel construction resists corrosion and wear, ensuring long‑term, high‑volume use.
The LT‑1160 complies with ASTM D240, ASTM D5865, and ISO 1928 standards, ensuring test results meet global benchmarks. USB/RS232 connectivity and PC software integration allow for data logging, graph plotting, and exportable reports, supporting GLP compliance and easy audits.
Despite its advanced functionality, the LT‑1160 maintains a compact footprint, fitting seamlessly into existing workflows. Its robust design, low maintenance needs, and competitive price point make it a smart investment for labs focused on efficiency and quality.
 High‑precision temperature resolution (0.001 °C)
 Automatic ignition, oxygen filling, and data capture
 Safety‑enhanced stainless‑steel combustion vessel
 Compliance with international test standards
 Integration with PC software for data management
Upgrade your lab with the Labtronics LT‑1160 Bomb Calorimeter to achieve dependable calorific measurements that support better decision‑making and regulatory compliance.
The Labtronics LT-671 Microprocessor Flame Photometer with a graphical display is engineered for fast and precise measurement of sodium and potassium ions in various sample solutions. Suitable for clinical labs, environmental analysis, and industrial testing, this instrument ensures high sensitivity and user-friendly operation for routine and advanced flame photometric applications.
The LT-29 Single Beam UV-Vis Spectrophotometer is a compact and reliable instrument for automatic concentration, % transmission, absorbance, and K factor measurements. It operates in a 195-1000 nm wavelength range and includes a 4-position selector sample holder for 10 mm path length cuvettes. The device supports printer interface for direct data output and comes with a set of 2 quartz and 4 glass cuvettes. Pre-installed software is included for seamless operation.
Buy LT-38 Digital Spectrophotometer with a dual display for more accurate spectral analysis. Covering a wavelength range of 340-960 nm, it features a 3½ digit data display and a separate 3-digit LED display for wavelength readings with 1 nm resolution. Includes provisions for 10 mm & 50 mm cuvettes for flexible sample analysis.
Buy LT-2100 Atomic Absorption Spectrophotometer (Single Beam) for reliable elemental analysis in laboratories and industries. Features a monochromator with 1800 lines/mm holographic grating, 0 to 2 nm SBW, and 190-900 nm wavelength range. Comes with a four-hollow cathode lamp turret, automatic calibration, built-in background correction, and a Titanium Burner for Air-Acetylene & N₂O-Acetylene flames.
Buy LT-40 Digital Spectrophotometer with double display technology for advanced spectral analysis. Offers a 340-960 nm wavelength range, automatic concentration measurement, and % Transmission and absorbance readings. Comes with a 3½ digit data display, a separate 3-digit LED wavelength display with 1 nm resolution, and support for 10 mm, 50 mm, and 100 mm cuvettes.
Agra | Firozabad | Hathras | Mathura | Vrindavan | Aligarh | Lucknow | Ambala | Mainpuri | Shikohabad | Alwar | Bhind | Bharatpur | Morena | Gwalior | Orai | Kanpur | Jhansi | Hardoi | Shahjahanpur | Lakhimpur | Pilibhit | Haldwani | Basti | Gorakhpur | Deoria | Azamgarh | Prayagraj | Varanasi | Sultanpur | Moradabad and more….
 
											Not a member? Create an account
Already got an account? Sign in here
By Clicking “Download Now”, you are confirming that you have read and agree to eqipped.com ‘s Terms of Use and Privacy Policy.
By Clicking “Join Now”, you are confirming that you have read and agree to eqipped.com ‘s Terms of Use and Privacy Policy.