Description
Specifications Table
| Product Name | Holmium, plasma standard solution, Specpure®, Ho 10,000µg/ml |
|---|---|
| Pack Size | 50ml, 100ml |
| Form | Liquid |
| Grade | Specpure® |
| Application | ICP, AAS, plasma spectroscopy |
Product Description
When precision matters in your lab, the right standard solution can make all the difference. The Holmium Plasma Standard Solution (Specpure®, 10,000µg/ml) is designed for researchers and analysts who demand accuracy in inductively coupled plasma (ICP) and atomic absorption spectroscopy (AAS). Whether you’re calibrating instruments or validating analytical methods, this high-purity holmium standard ensures consistent, reliable results every time.
Holmium is a critical element in rare earth analysis, often used as an internal standard in ICP-MS and ICP-OES due to its stable ionization properties. The Specpure® grade guarantees minimal impurities, making it ideal for trace element analysis where contamination could skew data. With a concentration of 10,000µg/ml, this solution offers flexibility for dilution to working standards, saving time and reducing errors in lab workflows.
At eqipped, we understand the challenges of sourcing high-quality lab supplies in India. That’s why we’ve partnered with trusted brands like Thermofisher to bring you standards that meet global benchmarks. Whether you’re a student setting up your first experiment or a seasoned researcher refining your methodology, this holmium standard is a dependable choice.
Need a reliable holmium standard for your next analysis? Order now and experience the difference precision makes.
Why Holmium Standards Matter in Your Lab
Holmium isn’t just another element on the periodic table—it’s a workhorse in analytical chemistry. Here’s why this standard is a staple in labs across India:
1. Internal Standard for ICP-MS/ICP-OES: Holmium’s unique mass spectrum and ionization efficiency make it a preferred internal standard for correcting instrument drift and matrix effects. If you’re analyzing complex samples like geological materials or environmental matrices, holmium helps normalize signals for accurate quantification.
2. Calibration and Validation: Whether you’re running quality control checks or developing new methods, a high-purity holmium standard ensures your instrument is calibrated correctly. The 10,000µg/ml concentration allows for easy dilution to lower working ranges, giving you control over your experimental setup.
3. Rare Earth Element Research: Holmium is part of the lanthanide series, and its behavior in plasma conditions is well-documented. Researchers studying rare earth elements in minerals, alloys, or industrial processes rely on standards like this to verify their findings.
4. Educational Use: For students learning spectroscopy techniques, working with a Specpure® standard means fewer variables to troubleshoot. It’s an excellent tool for teaching calibration curves, interference studies, and method development in academic labs.
Upgrade your lab’s accuracy today. Buy Holmium Plasma Standard Solution online and get it delivered to your doorstep.
Applications in Real-World Research
This holmium standard isn’t just for textbooks—it’s used in real-world applications where precision is non-negotiable:
Environmental Testing: Detecting holmium in soil or water samples can indicate rare earth mining activity or industrial pollution. Labs use this standard to quantify trace levels with confidence.
Material Science: In the development of high-performance alloys and ceramics, holmium’s presence can affect material properties. Accurate standards help engineers fine-tune compositions.
Pharmaceutical Analysis: While not a common pharmaceutical element, holmium standards are used in labs that analyze drug formulations for trace metal impurities, ensuring compliance with regulatory limits.
Geological Surveys: Holmium is found in minerals like monazite and bastnäsite. Geologists use standards like this to map rare earth deposits and assess their economic viability.
From research to routine testing, this holmium standard is your partner in precision. Shop now and take the guesswork out of your analysis.
Handling and Storage Guidelines
To maintain the integrity of your Holmium Plasma Standard Solution, follow these best practices:
Storage: Store the solution in its original container at room temperature (15–25°C). Keep the bottle tightly sealed to prevent evaporation or contamination. Avoid exposure to direct sunlight or heat sources.
Handling: Use standard lab safety protocols. While holmium is not highly toxic, always wear nitrile gloves and safety goggles when handling. Work in a well-ventilated area or under a fume hood if diluting the standard.
Dilution: For preparing working standards, use ultrapure water (18.2 MΩ·cm) and grade-A volumetric flasks to ensure accuracy. Follow your lab’s SOPs for dilution procedures to minimize errors.
Shelf Life: When stored correctly, this standard remains stable for 24 months from the date of manufacture. Check the expiration date on the label and recalibrate if the solution is past its prime.
Need a fresh batch for your next project? Order Holmium Plasma Standard Solution online and restock your lab with confidence.
Risk Note
Caution: While holmium is considered low in toxicity, this solution contains nitric acid as a stabilizer. Avoid skin contact, ingestion, or inhalation. In case of spillage, neutralize with a weak base (e.g., sodium bicarbonate) and dispose of according to local hazardous waste regulations. Always refer to the Safety Data Sheet (SDS) for detailed handling instructions.
FAQs
What is the difference between Specpure® and other grades of holmium standards?
Specpure® standards are manufactured with ultra-high purity, ensuring minimal interference from other elements. This makes them ideal for trace analysis where even ppb-level contaminants can affect results. Lower-grade standards may contain impurities that skew data, especially in ICP-MS applications.
Can I use this holmium standard for both ICP-OES and ICP-MS?
Yes, this 10,000µg/ml holmium standard is suitable for both techniques. For ICP-MS, you may need to dilute it further to avoid detector saturation, while ICP-OES can often handle higher concentrations depending on your instrument’s linear range.
How do I prepare a 1 ppm holmium working standard from this solution?
To prepare a 1 ppm (1µg/ml) standard, dilute 100µl of the 10,000µg/ml solution to 100ml with 2% nitric acid (or your matrix-matching acid). Use a class-A volumetric flask for accuracy. For example: 100µl stock + 99.9ml diluent = 1ppm Ho.
Is this holmium standard compatible with organic solvents?
This solution is aqueous-based (nitric acid matrix) and not designed for direct use with organic solvents. If you need a holmium standard in an organic matrix (e.g., for oil analysis), consider a organometallic standard or consult eqipped’s team for alternatives.
What is the typical lead time for delivery in India?
eqipped ensures fast dispatch for all orders. Delivery times vary by location: metro cities (2–4 days), Tier 2 cities (4–6 days), and remote areas (7–10 days). Expedited shipping options are available at checkout for urgent requirements.