Tetrabutylammonium phosphate monobasic, 0.4M solution in acetonitrile, AcroSeal® | 435991000 | Thermofisher

Thermo Fisher Scientific Chemicals Dealer | eqipped

Tetrabutylammonium phosphate monobasic, 0.4M solution in acetonitrile, AcroSeal® | 435991000 | Thermofisher

0.4M tetrabutylammonium phosphate monobasic solution in acetonitrile, ideal for HPLC and electrochemical applications. High-purity AcroSeal® grade.

31,838.00

Description

Specifications Table

Product NameTetrabutylammonium phosphate monobasic, 0.4M solution in acetonitrile, AcroSeal®
Pack Size100ML
FormLiquid solution
GradeAcroSeal® (HPLC grade)
ApplicationHPLC electrolyte, electrochemical studies, ion-pairing reagent

Product Description

When precision matters in your lab work, the right electrolyte solution can make all the difference. Tetrabutylammonium phosphate monobasic, commonly known as TBAP, is a high-purity 0.4M solution in acetonitrile that serves as a reliable electrolyte for HPLC and electrochemical applications. This AcroSeal® product from Thermofisher ensures consistent performance, making it a trusted choice for researchers and analysts who demand accuracy.

Whether you’re working on ion chromatography, electrochemical studies, or HPLC separations, this solution provides the stability and conductivity needed for reproducible results. The acetonitrile solvent enhances solubility, while the tetrabutylammonium cation improves ion-pairing efficiency. It’s an essential reagent for labs focusing on analytical chemistry, pharmaceutical research, or environmental testing.

At eqipped, we understand the importance of quality reagents in your experiments. That’s why we source this product directly from Thermofisher, ensuring you receive a solution that meets the highest standards. The 100 mL pack size is ideal for frequent use without excessive storage concerns, making it a practical choice for both academic and industrial labs.

Need a reliable electrolyte solution for your HPLC or electrochemical work? Buy tetrabutylammonium phosphate solution online today and experience consistent, high-quality results.

The versatility of this solution extends beyond HPLC. It’s also widely used in cyclic voltammetry and other electrochemical techniques where a stable supporting electrolyte is required. The 0.4M concentration strikes a balance between conductivity and solubility, reducing the risk of precipitation while maintaining optimal performance. For researchers working with sensitive detectors, this solution minimizes background noise, ensuring cleaner data.

Safety is always a priority when handling chemical solutions. While this product is designed for lab use, proper handling procedures should be followed. Store the solution in a cool, dry place away from direct sunlight, and always use appropriate personal protective equipment when handling. The AcroSeal® packaging ensures minimal exposure to moisture and contaminants, preserving the integrity of the solution until you’re ready to use it.

For labs that require consistent batch-to-batch performance, this Thermofisher product delivers. The rigorous quality control processes behind AcroSeal® reagents mean you can trust the purity and concentration specified on the label. Whether you’re a student setting up your first HPLC experiment or a seasoned researcher optimizing an electrochemical method, this solution provides the reliability you need.

Ready to elevate your lab’s analytical capabilities? Shop now for tetrabutylammonium phosphate monobasic solution and get fast delivery across India.

FAQs

What is tetrabutylammonium phosphate used for in HPLC?

Tetrabutylammonium phosphate acts as an ion-pairing reagent in HPLC, improving the separation of ionic compounds by forming neutral ion pairs that interact more effectively with the stationary phase. It’s particularly useful for separating organic acids, bases, and other charged analytes.

Can this solution be used for electrochemical studies?

Yes, the 0.4M TBAP in acetonitrile is an excellent supporting electrolyte for electrochemical techniques like cyclic voltammetry and chronoamperometry. Its stability and conductivity make it ideal for studying redox reactions and electron transfer processes.

How should I store this solution to maintain its stability?

Store the solution in its original AcroSeal® container at room temperature, away from direct sunlight and moisture. Keep the bottle tightly sealed when not in use to prevent solvent evaporation and contamination. Proper storage ensures the solution remains stable for its entire shelf life.

Is this product compatible with all HPLC columns?

While this solution works well with most reverse-phase HPLC columns, it’s important to check compatibility with your specific column type. Some specialty columns may have restrictions on certain mobile phase additives. Always refer to your column manufacturer’s guidelines.

What safety precautions should I take when handling this solution?

Wear nitrile gloves, safety goggles, and a lab coat when handling this solution. Work in a fume hood to avoid inhaling acetonitrile vapors. Avoid skin contact and wash thoroughly after use. Keep away from open flames or heat sources due to the flammable nature of acetonitrile.

Additional information

Size

100ML, 100ML

Do You Want Best Price?

Take 3 minutes to share your Details.