Water EL Grade 1 LT

Thermo Fisher Scientific Chemicals Dealer | eqipped

Water EL Grade 1 LT

Ultra-pure EL Grade 1 water with low TOC and resistivity >18 MΩ·cm. Essential for HPLC, molecular biology, and trace analysis.

Original price was: ₹19,999.00.Current price is: ₹13,999.00.

Specifications Table

Product Name – Water EL Grade 1 LT
Quantity/Pack Size – 1 LT
Form – Liquid
Grade – EL Grade 1 (Ultra-Pure)
Application – HPLC, molecular biology, trace analysis, reagent preparation

Product Overview

EL Grade 1 water is a high-purity laboratory reagent designed for applications demanding ultra-low contamination levels. Produced through advanced purification processes including reverse osmosis, deionization, and microfiltration, this water meets stringent specifications with resistivity exceeding 18 MΩ·cm at 25°C and total organic carbon (TOC) levels below 5 ppb. Its ultra-low particulate and bacterial content make it indispensable for sensitive analytical techniques where even trace impurities can compromise results. The water is packaged in high-density polyethylene (HDPE) containers to prevent leaching and maintain purity during storage. Unlike standard distilled water, EL Grade 1 undergoes additional polishing steps to remove residual ions, organics, and nucleases, ensuring consistency across critical laboratory workflows. The sealed packaging includes tamper-evident features to guarantee integrity upon delivery. This grade is particularly valued in environments where water quality directly impacts experimental reproducibility, such as in chromatographic separations or nucleic acid amplification protocols.

FAQs

1. What is the shelf life of EL Grade 1 water once opened?

Once opened, the water should be used within 2-3 days for critical applications, as exposure to air may introduce contaminants. For extended storage, transfer to a sterile, tightly sealed container and use within 1 week.

2. Can this water be used for cell culture applications?

While EL Grade 1 water meets many purity requirements, cell culture typically requires additional supplementation with nutrients and buffers. For direct cell culture use, consider sterile, endotoxin-tested water specifically labeled for biological applications.

3. How does EL Grade 1 differ from Type I reagent water?

EL Grade 1 water aligns with Type I specifications but undergoes additional quality controls for consistency. Both meet resistivity and TOC standards, though EL Grade 1 is often preferred for its stricter particulate and microbial limits in specialized applications.

4. Is this water compatible with glassware washing for trace analysis?

Yes, EL Grade 1 water is suitable for final rinsing of glassware used in trace metal analysis, provided the glassware is pre-cleaned with acid or detergent to remove organic residues. Avoid using it as the sole cleaning agent for heavily contaminated items.

5. What precautions should be taken during handling to maintain purity?

Always use powder-free gloves and sterile pipettes when dispensing. Avoid pouring directly from the container; instead, use a dedicated dispensing system or aliquot into sterile secondary containers to minimize contamination risks.

Thermo Fisher Scientific Chemicals Dealer | eqipped

Water EL Grade 1 LT

Original price was: ₹19,999.00.Current price is: ₹13,999.00.

Ultra-pure EL Grade 1 water with low TOC and resistivity >18 MΩ·cm. Essential for HPLC, molecular biology, and trace analysis.

Specifications Table

Product Name – Water EL Grade 1 LT
Quantity/Pack Size – 1 LT
Form – Liquid
Grade – EL Grade 1 (Ultra-Pure)
Application – HPLC, molecular biology, trace analysis, reagent preparation

Product Overview

EL Grade 1 water is a high-purity laboratory reagent designed for applications demanding ultra-low contamination levels. Produced through advanced purification processes including reverse osmosis, deionization, and microfiltration, this water meets stringent specifications with resistivity exceeding 18 MΩ·cm at 25°C and total organic carbon (TOC) levels below 5 ppb. Its ultra-low particulate and bacterial content make it indispensable for sensitive analytical techniques where even trace impurities can compromise results. The water is packaged in high-density polyethylene (HDPE) containers to prevent leaching and maintain purity during storage. Unlike standard distilled water, EL Grade 1 undergoes additional polishing steps to remove residual ions, organics, and nucleases, ensuring consistency across critical laboratory workflows. The sealed packaging includes tamper-evident features to guarantee integrity upon delivery. This grade is particularly valued in environments where water quality directly impacts experimental reproducibility, such as in chromatographic separations or nucleic acid amplification protocols.

FAQs

1. What is the shelf life of EL Grade 1 water once opened?

Once opened, the water should be used within 2-3 days for critical applications, as exposure to air may introduce contaminants. For extended storage, transfer to a sterile, tightly sealed container and use within 1 week.

2. Can this water be used for cell culture applications?

While EL Grade 1 water meets many purity requirements, cell culture typically requires additional supplementation with nutrients and buffers. For direct cell culture use, consider sterile, endotoxin-tested water specifically labeled for biological applications.

3. How does EL Grade 1 differ from Type I reagent water?

EL Grade 1 water aligns with Type I specifications but undergoes additional quality controls for consistency. Both meet resistivity and TOC standards, though EL Grade 1 is often preferred for its stricter particulate and microbial limits in specialized applications.

4. Is this water compatible with glassware washing for trace analysis?

Yes, EL Grade 1 water is suitable for final rinsing of glassware used in trace metal analysis, provided the glassware is pre-cleaned with acid or detergent to remove organic residues. Avoid using it as the sole cleaning agent for heavily contaminated items.

5. What precautions should be taken during handling to maintain purity?

Always use powder-free gloves and sterile pipettes when dispensing. Avoid pouring directly from the container; instead, use a dedicated dispensing system or aliquot into sterile secondary containers to minimize contamination risks.

My Cart
Recently Viewed
Categories

Join Eqipped Circle

By Clicking “Join Now”, you are confirming that you have read and agree to eqipped.com ‘s Terms of Use and Privacy Policy.

Collaborate With Us

By Clicking “Download Now”, you are confirming that you have read and agree to eqipped.com ‘s Terms of Use and Privacy Policy.

💬
Eqipped

Get Price and available Brands of Product, I’d love to help you 😊

×